DCP-2K4 to ShowVault-4
Conversion Procedure
Digital Cinema Server
Version 1.2
The information contained herein is confidential and may not be
divulged to any person or entity or reproduced, disseminated or
disclosed, in whole or in part. By receipt of this material including
any exhibits, attachments and spreadsheets the recipient agrees
that the information contained herein shall be kept confidential and
shall not, without the prior written consent of Doremi Laboratories,
be disclosed by the recipient in any manner.
SHV.DP.001968.DRM Page 1 Version 1.2
Doremi Cinema LLC Confidential
Page view 0
1 2 3 4 5 6 ... 26 27

Summary of Contents

Page 1 - DCP-2K4 to ShowVault-4

DCP-2K4 to ShowVault-4Conversion ProcedureDigital Cinema ServerVersion 1.2The information contained herein is confidential and may not be divulged to

Page 2 - Table of Contents

4 Unit PreparationCAUTION: During the procedure presented in this document, you will have to remove screws from the unit. Make sure NOT to lose the s

Page 3 - 1 Introduction

5 Conversion Procedure• The lid needs to be removed. Unscrew the six screws with the Phillips screwdriver. There are two screws on each side and two

Page 4 - 2.2 Required Parts

Figure 22: Screw on Motherboard: 1.0 E Dolphin• Remove the screw holding the Dolphin card on the top of the rear chassis (Figure 23).Figure 23: Screw

Page 5

Figure 25: Dolphin Card Removal- 1.2 FFigure 26: Dolphin Card Removal- 1.0 E• For 1.0 E Dolphins, remove the Dolphin stand-off (Figure 27) on the moth

Page 6

Figure 28: Motherboard Screw on 1.0 E Dolphin• Unplug the IDC cable from the Dolphin card (Figure 29).Figure 29: Unplugging the IDC Cable• Unplug the

Page 7 - 2.3 Required Accessories

Figure 31: Unplugging Ethernet Cable for the 1.2 F Dolphin• Unplug the SBC power connector cable from the Dolphin Card (Figure 32).Figure 32: Unpluggi

Page 8

Figure 34: Removing the Ethernet Cable for the 1.2 F Dolphin• Tuck the SBC cable underneath the DVD and CRU, using the mounting clip underneath to hol

Page 9 - 3 ESD Rules

Figure 37: AES Card Being Removed• Unscrew the two nuts holding the card in place using the nut driver and remove the card so that the bracket looks l

Page 10 - 4 Unit Preparation

Figure 41: AES Bracket in Place• Remove the DPT cover by unscrewing the screw on the motherboard, located at MH8 (Figure 42). Figure 42: Motherboard S

Page 11 - 5 Conversion Procedure

Figure 44:Slots After• Insert the PCI-e card provided in the PCI-e slot located on the motherboard. Push down slightly on the card until it clicks int

Page 12

Table of Contents1 Introduction...

Page 13

Figure 46: Dolphin Stand-off on 1.2 F DolphinFigure 47: Motherboard Screw on 1.2 F Dolphin• Remove the 1 GB RAM modules from the motherboard by pressi

Page 14

Figure 49: 2G RAM Modules• Gently insert the 2GB modules into the RAM slots. Apply pressure evenly until the modules snap into place. • Place the old

Page 15

5.1 Stickers• Place the ShowVault sticker provided over the DCP-2K4 sign on the front panel (Figure51).Figure 51: ShowVault Sticker in Place• Place th

Page 16 - Ethernet

Figure 53: Serial Number StickerThe hardware installation is now complete. 5.2 Assigning the Chassis Serial Number Because the Chassis Serial number f

Page 17

Figure 54: About Window• Diagnostic Tool Window :◦ Go to Menu → Diagnostic Tool and check the chassis number entry as illustrated below (Figure 55):

Page 18

• Select “hotfix_pcie_2GiB-1.0.0.pkg” and any licenses that appear in the Ingest window.• Click the Ingest button.• After ingesting, reboot the unit.

Page 19

7 Acronyms Term DefinitionDLM Doremi License MessageDPT Dolphin Plastic TunnelIMB Integrated Media BlockPCI-e Peripheral Component Interconnect Expre

Page 20

8 Document Revision HistoryDate Version Description12/01/2011 1.0 First version.03/19/2012 1.1 Minor revisions made.09/05/2012 1.2 RAM update added.

Page 21

1 Introduction1.1 PurposeThis document details how to convert a DCP-2K4 to a ShowVault-4. It is presented as a step-by-step procedure that must have

Page 22 - 5.1 Stickers

2 Required Components for ConversionCAUTION: Make sure you have all the parts listed below before beginning the conversion procedure.2.1 Required To

Page 23

• 3 M3 Screws (Doremi Part Number: M3x6MM-LW)Figure 5: M3 Screws• 1 Motherboard Screw (Doremi Part Number: P632x6MM-LW)Figure 6:Motherboard Screw• 1

Page 24 - Package

◦ Christie (Doremi Part Number IMB-C)Figure 9: IMB Christie◦ NEC (Doremi Part Number IMB-N)Figure 10: IMB NEC• 2 RAM Modules totaling 2GB (Doremi Par

Page 25 - 6 Returning the Media Block

• Chassis Revision Number and Serial Number StickersFigure 12: Revision Number and Serial Number Stickers2.3 Required Accessories The following parts

Page 26 - 7 Acronyms

Figure 15: GPIO Cable• 2 Twelve Inch Ethernet Cables (Doremi Part Number: CBL-ENET-12IN)Figure 16: Ethernet Cables• RJ45 to DB25 AES Adapter (Doremi P

Page 27 - 8 Document Revision History

3 ESD RulesESD (Electrostatic Discharge) safety rules are to be respected while assembling, repairing, or upgrading hardware on all Doremi products.